Busca Unidad Fan Coil, Unidad Fan Coil Oculta, Unidad De Bobina De Ventilador De Casete en el directorio Industry, Reliable fabricante / proveedor / fábrica de China
productos nuevos
Tipo de Pago: | L/C, T/T, Western Union |
---|---|
Cantidad de pedido mínima: | 1 |
Plazo de entrega: | 1 días |
Modelo: EKDW020S
Cabinet type Air handing units | ||||||||||||
Model | EKDW020S | EKDW030S | EKDW040S | EKDW050S | EKDW060S | EKDW070S | EKDW080S | EKDW090S | EKDW100S | EKDW120S | ||
Nominal air flow (m³/h) | 2000 | 3000 | 4000 | 5000 | 6000 | 7000 | 8000 | 9000 | 10000 | 12000 | ||
Nominal cooling capacity (KW) | 4 rows of coils (return air) | 12 | 17 | 24 | 31 | 38 | 44 | 51 | 56 | 63 | 74 | |
4 rows of coils (fresh air) | 29 | 42 | 57 | 69 | 83 | 94 | 113 | 127 | 142 | 169 | ||
6 rows of coils (return air) | 15 | 23 | 33 | 39 | 48 | 55 | 63 | 72 | 78 | 94 | ||
6 rows of coils (fresh air) | 35 | 53 | 69 | 88 | 105 | 122 | 137 | 155 | 173 | 208 | ||
Nominal heating capacity (KW) | 4 rows of coils (return air) | 19 | 30 | 41 | 50 | 61 | 71 | 83 | 93 | 103 | 122 | |
4 rows of coils (fresh air) | 33 | 49 | 66 | 82 | 99 | 115 | 133 | 148 | 161 | 197 | ||
6 rows of coils (return air) | 23 | 36 | 48 | 60 | 72 | 84 | 96 | 108 | 120 | 144 | ||
6 rows of coils (fresh air) | 38 | 57 | 77 | 95 | 114 | 132 | 150 | 169 | 188 | 224 | ||
Nominal cooling water flow (L/S) | 4 rows of coils (return air) | 0.57 | 0.81 | 1.14 | 1.48 | 1.81 | 2.1 | 2.43 | 2.67 | 3 | 3.52 | |
4 rows of coils (fresh air) | 1.38 | 2 | 2.71 | 3.29 | 3.95 | 4.48 | 5.38 | 6.05 | 6.76 | 8.05 | ||
6 rows of coils (return air) | 0.71 | 1.1 | 1.57 | 1.86 | 2.29 | 2.62 | 3 | 3.43 | 3.71 | 4.48 | ||
6 rows of coils (fresh air) | 1.67 | 2.52 | 3.29 | 4.19 | 5 | 5.81 | 6.52 | 7.38 | 8.24 | 9.9 | ||
Nominal heating water flow (L/S) | 5 rows of coils (return air) | 0.43 | 0.68 | 0.92 | 1.13 | 1.37 | 1.71 | 1.87 | 2.24 | 2.32 | 2.75 | |
5 rows of coils (fresh air) | 0.74 | 1.1 | 1.49 | 1.85 | 2.23 | 2.77 | 2.99 | 3.56 | 3.62 | 4.44 | ||
7 rows of coils (return air) | 0.52 | 0.81 | 1.08 | 1.35 | 1.62 | 2.02 | 2.16 | 2.6 | 2.7 | 3.24 | ||
7 rows of coils (fresh air) | 0.86 | 1.28 | 1.73 | 2.14 | 2.57 | 3.17 | 3.38 | 4.06 | 4.23 | 5.04 | ||
Coil | Type | Copper tube with a new type of wavy aluminum fins | ||||||||||
Piece / inch | 13 | |||||||||||
Working pressure (MPa) | 1.6 | |||||||||||
Size of inlet/outlet water pipe connector | R 1-1/2 | R 1-1/2 | R 1-1/2 | R 1-1/2 | R 1-1/2 | R 2 | R 2 | R 2 | R 2 | R 2 | ||
Size of condensate water pipe connector | R 1-1/4 | |||||||||||
Fan | Type / material | High-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates | ||||||||||
Transmission | V-belt transmission | |||||||||||
Fanning direction | Downward horizontal / top | |||||||||||
Rang (number of nozzles) | 4 rows of heat exchangers | I | 10~20m(1) | 10~20m(2) | 10~20m(2) | 10~20m(2) | 10~20m(2) | 10~20m(2) | 10~20m(2) | 10~20m(2) | ~ | ~ |
II | 20~30m(1) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | ||
III | ~ | ~ | ~ | 30~40m(1) | 30~40m(2) | 30~40m(1) | 30~40m(1) | 30~40m(1) | 30~40m(2) | 30~40m(2) | ||
6 rows of heat exchangers | I | 10~20m(1) | 10~20m(2) | 10~20m(2) | 10~20m(2) | 10~20m(2) | 10~20m(2) | 10~20m(2) | 10~20m(2) | ~ | ~ | |
II | 20~30m(1) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | 20~30m(2) | ||
III | ~ | ~ | ~ | 30~40m(1) | 30~40m(2) | 30~40m(1) | 30~40m(1) | 30~40m(1) | 30~40m(2) | 30~40m(2) | ||
Motor power (kw) | 4 rows of heat exchangers | I | 0.55 | 0.75 | 0.75 | 1.1 | 1.5 | 1.5 | 1.5 | 2.2 | ~ | ~ |
II | 0.75 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 2.2 | 3 | 3 | 4 | ||
III | ~ | ~ | ~ | 2.2 | 3 | 3 | 3 | 4 | 5.5 | 5.5 | ||
6 rows of heat exchangers | I | 0.75 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 2.2 | 3 | 3 | 4 | |
II | 1.1 | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | 2.2 | 3 | 3 | 4 | ||
III | ~ | ~ | ~ | 2.2 | 3 | 3 | 3 | 4 | 5.5 | 5.5 | ||
Fliter | Type | Thickness (mm) | ||||||||||
Thickness (mm) | 8/21 | |||||||||||
Cabinet | Type | 30mm-thick double-layer plates filled with polyurethane material foamed under high pressure for heat presevation | ||||||||||
Unit dimension | Length (mm) | 820 | 950 | 1010 | 1130 | 1206 | 1300 | 1500 | 1620 | 1650 | 1750 | |
Wildth (mm) | 1450 | 1450 | 1550 | 1550 | 1550 | 1600 | 1600 | 1600 | 1550 | 1550 | ||
Height (mm) | 630 | 650 | 755 | 755 | 805 | 830 | 830 | 830 | 890 | 950 | ||
Unit weight (kg) | 4 rows of heat exchangers | 135 | 149 | 179 | 195 | 222 | 282 | 247 | 282 | 369 | 389 | |
6 rows of heat exchangers | 139 | 156 | 187 | 204 | 232 | 297 | 260 | 297 | 388 | 411 | ||
Note: | ||||||||||||
1. The above parameters are for standard units. However, EK can customize these parameters to meet special requirements from customers. | ||||||||||||
2. Working conditions for cooling under nominal return air flow: dry bulb 27 degree, wet bulb 19.5 degree; working conditions for cooling under nominal fresh air flow: dry bulb 34 degree, wet bulb 28 degree; water temperature under nominal cooling capacity: inlet water 7 degree, outlet water 12 degree. |
||||||||||||
3. Working conditions for heating under nominal return air flow: dry bulb 21 degree; Working conditions for heating under nominal fresh air flow: dry bulb 0 degree; water temperature under nominal heating capacity: inlet water 60 degree, outlet water 50 degree. |
||||||||||||
4.Weight listed in the above table are net weight of units. Operation weight may post an increase of 20%. | ||||||||||||
5. Parameters inside ( ) are the power of units with 6 rows of coils. | ||||||||||||
6. The coil loops for units with full return air ("R") and units with full fresh air ("F") may be different. Please specify the inlet air conditions while placing orders. We can provide computer-aided model selection to meet special requirements. For detailed parameters, please refer to the model selection results. |
Grupos de Producto : Unidad Fan Coil